National Repository of Grey Literature 6 records found  Search took 0.01 seconds. 
Model of cleaning station for food processing technology controlled by a control system na PROFIBUS network.
Vyskočil, Jaromír ; Sobotka, Milan (referee) ; Pásek, Jan (advisor)
This bachelor’s thesis deals with design, realization and laboratory commissioning of the model of keg / tank cleaning station (CIP) in foodstuff industry. The model uses two cleaning liquids – water and lye. There are several different types of valves used in the CIP model. They serves for inlet and outlet of lye or water and for separation of the both liquids branches. The control system offers monitoring of pressure, volume flow, level of the lye, etc. The measuring devises mostly communicate with PLC via industrial net PROFIBUS-DP and PA. The same net PROFIBUS-DP also provides communication between PLC and distributed control system Festo (valve island). Configuration and set up of the Festo valve island is described in the thesis as well. Further the work presents processing of the analogue values from different transmitters and their representation in a operator panel. Operator panel (OP) serves for control and visualization of the cleaning station. The OP configuration, the screens structure and the full functionality in the CIP station is explained. The individual screen description is incorporated as well. There are three modes of control – manual, semiautomatic and automatic. Automatic control is based on the recipe concept and the cleaning philosophy is split into several phases. The PLC control is presented in the form of flow diagrams algorithms and the program code in STEP7 is enclosed in attachment on CD ROM.
Assessment of time variations in the accuracy of reported discharge and passed volume in measuring systems using flume
Šamánek, Radek ; Ježek, Jiří (referee) ; Žoužela, Michal (advisor)
The diploma thesis deals with monitoring of metrological characteristics of ultrasonic sensors located at the FAST and in-situ and the evaluation of the time development in the values of the discharge and the outflow volumes reported by the ultrasonic sensors.
The timeline of the development of meteorological characteristics of water level ultrasonic sensors
Šamánek, Radek ; Zubík, Pavel (referee) ; Žoužela, Michal (advisor)
The bachelor’s thesis deals with collection and evaluation of data from selected water level measuring sensors which are installed in-situ and in laboratory conditions. By comparing actual and measured water levels and its statistic evaluation, trends were determined in the timeline development of measuring capabilities of relevant ultrasonic sensors.
Assessment of time variations in the accuracy of reported discharge and passed volume in measuring systems using flume
Šamánek, Radek ; Ježek, Jiří (referee) ; Žoužela, Michal (advisor)
The diploma thesis deals with monitoring of metrological characteristics of ultrasonic sensors located at the FAST and in-situ and the evaluation of the time development in the values of the discharge and the outflow volumes reported by the ultrasonic sensors.
The timeline of the development of meteorological characteristics of water level ultrasonic sensors
Šamánek, Radek ; Zubík, Pavel (referee) ; Žoužela, Michal (advisor)
The bachelor’s thesis deals with collection and evaluation of data from selected water level measuring sensors which are installed in-situ and in laboratory conditions. By comparing actual and measured water levels and its statistic evaluation, trends were determined in the timeline development of measuring capabilities of relevant ultrasonic sensors.
Model of cleaning station for food processing technology controlled by a control system na PROFIBUS network.
Vyskočil, Jaromír ; Sobotka, Milan (referee) ; Pásek, Jan (advisor)
This bachelor’s thesis deals with design, realization and laboratory commissioning of the model of keg / tank cleaning station (CIP) in foodstuff industry. The model uses two cleaning liquids – water and lye. There are several different types of valves used in the CIP model. They serves for inlet and outlet of lye or water and for separation of the both liquids branches. The control system offers monitoring of pressure, volume flow, level of the lye, etc. The measuring devises mostly communicate with PLC via industrial net PROFIBUS-DP and PA. The same net PROFIBUS-DP also provides communication between PLC and distributed control system Festo (valve island). Configuration and set up of the Festo valve island is described in the thesis as well. Further the work presents processing of the analogue values from different transmitters and their representation in a operator panel. Operator panel (OP) serves for control and visualization of the cleaning station. The OP configuration, the screens structure and the full functionality in the CIP station is explained. The individual screen description is incorporated as well. There are three modes of control – manual, semiautomatic and automatic. Automatic control is based on the recipe concept and the cleaning philosophy is split into several phases. The PLC control is presented in the form of flow diagrams algorithms and the program code in STEP7 is enclosed in attachment on CD ROM.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.